Fiber cement siding should be at least 6" above the grade level of the house. There should also be a 1"-2" gap between horizontal surfaces like steps, decks, or adjacent roofs. Note : If you're working alone, you can use overlap gauges to help support the siding while you nail it.
HardiePanel, also composed of fiber-cement, is the tall, vertical version of HardiePlank, at 48 inches wide by 96 inches to 120 inches long. Fiber Cement Siding and Resale Value With other types of siding, particularly vinyl siding, it is debatable whether you will be able to make back your initial investment when it comes time to sell the house.
Vertical cracks are often caused by the shrinking of concrete as it cures; if the edges of a small crack feel even as you run your fingers along the sides, this is likely the reason why. However, it's always a good idea to have a professional look at the problem, so you can be sure that the problem is not major before it gets much worse.
Retaining walls are structure used to retain soil, rock or other materials in a vertical condition. Hence they provide a lateral support to vertical slopes of soil that would otherwise collapse into a more natural shape. Most common materials used for retaining walls are:
Vertical closed-loops (VCLs) are a type of heat exchanger used with many geothermal heat ... Cementitious grout - means a mixture of the following components, or other cement-based admixtures designed for geothermal applications as recommended by the department prior to use: 1. Six and two-tenths (6.2) gallons of fresh water.
Step 3 | Prime The Cinder Block Planters. For priming, make sure the blocks are completely dry otherwise, the paint will peel off from the moisture leftover in the blocks. Apply the primer with one of the 9″ rollers. I used the second roller for applying the …
FORM. / CSG TVD MD CASING PROFILEHOLE SIZE CSG SPECS MUD INFO NOTES 50' 50' 20" Excess Shallow Shales 17 1/2' Cmt to Surf. Vertical < 2º 13 3/8", J-55
I mixed batches of cement, going for a pretty thick consistency that would stay up on a vertical surface. I used a soaked sponge to wet the bricks and mortar, making it easier for the cement to get a good bond. To apply the cement, I grabbed a good handful, and worked it into the right shape, breaking up any clumps.
By and large, the lean concrete mix proportions is 1:4:8 (1 Cement : 4 Fine aggregate : 8 Coarse aggregate) or 1 : 5 : 10 ( 1 Cement : 5 Fine aggregate : 10 Coarse aggregate) mix ; The angular spread of load from the wall should not be more than 1 vertical to 112 horizontals in masonry and 1 vertical to 1 horizontal for cement concrete.
Vertical Concrete Cylinder Capper. Manufacturer: Humboldt Humboldt - H-2952 For capping 6" dia. x 12" high (152 x 305 mm) concrete test cylinder s when making compression tests. Simplifies capping process by assuring plane end surfaces are right angles to axis of the cyl...
Advantages of Cement Verticle Mill: The vertical milling system has simple process, compact layout and small building area. The floor space is about 70% of the ball mill system. The building space is about 60% of the ball mill system and can be arranged in the open air, which directly reduces the investment cost of the enterprise.
Enter your zip code, and we'll customize this site to show you the unique combination of James Hardie fiber cement products and ColorPlus® colors available near you. Color and Design. Color and Design; House Siding Ideas Gallery ... Hardie® Panel Vertical Siding .
Vertical cracks tend to slant slightly (within 30 degrees). To seal them, water-resistant epoxy or polyurethane injection is applied to the cracks. Once you fix the issues, you can protect your foundation from future cracks by clearing clogged gutters and using downspouts that extend 5 ft. away from the foundation walls.
Building codes have requirements on how close rebar may be to the earth (soil) as well as how close it may be to concrete forms. The distances vary upon the location and size of the rebar. Common rebar sizes used in residential construction for houses are usually in sizes ranging from #3 rebar to #6 rebar. # 4 rebar has a diameter of 1/2 inch ...
Control Joints for Concrete Masonry Walls – Empirical Method, TEK 10-2C. National Concrete Masonry Association, 20010. Standard Specification for Loadbearing Concrete Masonry Units, ASTM C 90-02. American Society for Testing and Materials, 2002. Standard Test Method for Linear Drying Shrinkage of Concrete Block, ASTM C 426-99.
Fiber cement board lap siding repair guide. This article describes repair procedures for cosmetic or functional siding issues that may arise such as loose siding, wind-damaged siding, siding paint or coating failures, and siding gaps, especially gaps at fiber cement siding butt joints where lap siding is installed. Our page top photo shows loose and improperly installed fiber cement …
Even though I've shown in other videos how to make this mix, I have had inquiries as to how to make a concrete mix that is like clay that can be shaped, mold...
Key to Figure 6.2 Fireplace. Chimney—A vertical masonry shaft of reinforced concrete or other approved noncombustible, heat resisting material enclosing one or more flues.It removes the products of combustion from solid, liquid or gaseous fuel. Flue liner—The flue is the hole in the chimney.The liner, made of terra cotta or metal, protects the brick from harmful smoke gases.
Concrete wall saws are typically used on vertical surfaces when a new doorway, window or HVAC openings are needed. Wall sawing employs a diamond blade on a track-mounted system that can be used for vertical or horizontal cuts. These saws run on hydraulic or electric power and are also commonly referred to as concrete track saws.
i. Vertical cracks in walls built with concrete blocks or sand lime bricks. Cracks generally occur at weak sections, i.e., at midpoints or at regular intervals in long stretches. The cracks may be straight or toothed. ii. Vertical cracks at the junctions …
Introducing: Waterproof Cement Backer Board*. The most preferred brand of backer board** is now even better. The all-new HardieBacker® Cement Board with HydroDefense™ Technology delivers a waterproof composition throughout the board–and rock solid protection for your customers, your work, and your reputation. Learn more.
Contact us for more information at info@ctscement OR 800-929-3030.
Use of plastic or concrete spacers is allowed to keep rebar off the ground when pouring. If there is a poured concrete or masonry wall on top of the footing, you'll need #3 or greater vertical rebar at a minimum of 48" on center. These bars have hooks at the bottom extending laterally towards the edge of the footing.
What is a stem wall? A type of foundation common in much of the United States, stem walls are short (up to several feet, or the height of a crawl space) and are attached to a concrete footing. They are typically used in houses with crawl spaces, either vented or unvented, and are especially common in California, Texas, the Northwest, and the South.
controlled low-strength material (CLSM), or lean concrete sub-base. Generally cement treated and lean concrete sub-bases are 4 to 6 inches thick. A modulus of sub-grade reaction of 400 to 500 psi/inch can be used in calculating the required thickness of floors placed directly on lean concrete and cement treated or roller compacted sub-bases.
AND CONCRETE SLAB SYSTEMS 1-1 CONCRETE Concrete, the most commonly used construction mate-rial worldwide, is a composite material that consists primarily of a mixture of cement and fine and coarse aggregates (sand, gravel, crushed rock, and/or other materials) to which water has been added as a neces-
LafargeHolcim is the nation's leading building materials, cement and concrete supplier solutions company serving builders, architects, engineers and masons. We provide ready mix concrete, self leveling cement, type II cement, and aggregates for projects of all sizes and challenges.
parallel to the vertical axis of the face of the wall. Stretcher. A masonry unit laid flat with its longest dimension parallel to the face of the wall. Wythe. A continuous vertical section or thickness of masonry 4" or greater. Brick Walls QUIKRETE® Mortar Mix or Mason Mix Bricks Chalk line Mortarboard Hose Wheelbarrow Trowel Level Carpenter's ...
The modified thinset used with our product is a fortified cement-based mortar and should specifically conform to ANSI (American National Standards Institute) A 118.4. The thinset can be fortified in a pre-mixed powder form or with a liquid additive. Can I use liquid nails or glue with HardieBacker® cement board? No.
James Hardie HardieTrim Fiber Cement Smooth 5/4 NT3 9.25"x144" Arctic White 1pc. $35.25. Add to Cart. Add to Compare. James Hardie HardieShingle Fiber Cement Straight Siding 15.25"x48" Night Gray 1pc. $12.90. Add to Cart. Add to Compare. James Hardie HardieShingle Fiber Cement Straight Siding 15.25"x48" Timber Bark 1pc.
Honeycombing in concrete looks like the honeycomb (honey bees nest).If the honeycomb is present in the surface of the structure, then it can be detected as soon as we remove the shuttering and if the honeycomb is present inside the mass concrete, then it requires advanced techniques like ultrasonic testing for its detection.
A concrete anchor is a steel shaft either cast into concrete at placement or post-installed after the concrete has hardened. Cast-in anchors are threaded shafts with a buried end termination of a hex head, threaded nut, or 90° (L-) or 180° (J-) hook, or headed (non-threaded) studs welded to a surface plate.
Usually a cement: sand mortar in the ratio of 1: 3 to 1: 4 is used for repair, in which the aggregate maximum size is 10 mm.; Cement mortar is pneumatically applied to concrete or masonry cracks.; The method is same which is mentioned above. 3. Installing Ferro-cement Plate at Corner: Wire mesh is used to repair brick wall defects likes cracks at the …
Anchoring too close to an edge or placing anchors too close to one another can decrease performance. For use. ... variables found in concrete, the tolerances of the carbide drills and anchors, the tools used to set them and most ... used on a vertical one with the exaggerated component loads on equipment in this position.
Allura's fiber cement vertical panels come in 4-foot widths, making nailing them directly to the studs an easy process. Studs are usually located every 16-inches or every 24-inches, depending on your home and frame.
1. Ordinary Portland Cement (OPC) Ordinary Portland cement is the most widely used type of cement, which is suitable for all general concrete construction. It is the most commonly produced and used type of cement around the world, with annual global production of around 3.8 million cubic meters per year.
How to Fill a Hole in the Exterior Concrete Wall of a Home Before Painting. In addition to being an eyesore, a hole in an exterior concrete wall of your home creates a point of weakness in the ...
Vertical scores of pocked concrete help create the illusion ...